Twicea electronic parts stores,electronic components,electronic parts,electronics parts supply Twicea electronic parts stores,electronic components,electronic parts,electronics parts supply
Categories Categories Manufacturers Manufacturers RFQ About Twicea
Capacitors
Memory Cards, Modules
Resistors
Isolators
Magnetics - Transformer, Inductor Components
Sensors, Transducers
Optoelectronics
Integrated Circuits (ICs)
Crystals, Oscillators, Resonators
Discrete Semiconductor Products
RF/IF and RFID
Switches
Transformers
Motors, Solenoids, Driver Boards/Modules
View All
Brands A-Z
3M
Infineon
Insight SiP
Isocom Components
Microchip
ON Semiconductor
STMicroelectronics
TDK
Xilinx
Yageo

Hello

OR
Create An Account
Profile Settings Order Status & History Address Management RFQ History WISH LIST Change Password
Cart
  • All Products
  • Connectors, Interconnects
  • Terminal Blocks - Headers, Plugs and Sockets
Image Part # Manufacturer Description Availability Pricing Quantity Factory Lead TimeContact PlatingMountMounting TypePackage / CaseMaterialHousing MaterialWeightContact MaterialsCurrent-IECCurrent-ULInsulation MaterialsVoltage RatedVoltage-IECOperating TemperaturePackagingPublishedSeriesTolerancePbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationECCN CodeConnector TypeTypeResistanceNumber of PositionsMin Operating TemperatureColorNumber of RowsGenderAdditional FeatureHTS CodePower RatingVoltage - Rated DCPitchOrientationDepthInsulation HeightReach Compliance CodeCurrent RatingTermination StyleVoltage - Rated ACCase Code (Metric)Approval AgencyCase Code (Imperial)Lead PitchNumber of ContactsContact GenderHousing ColorVoltageContact Tail LengthMax Supply VoltageMax Voltage Rating (AC)Max Current RatingNumber of LevelsCurrentWire Gauge (Max)Wire Gauge (Min)Wire/Cable GaugeNumber of PolesContact Mating FinishNumber of DecksWire Gauge or Range - AWGPositions Per LevelNumber of WaysSafety ApprovalPlug Wire EntryHeader OrientationWire Gauge or Range - mm²Wire Strip LengthNumber of Positions Per LevelScrew SizeStripping LengthWire Cross SectionFastening MethodMax Supply Voltage (DC)Max Supply Voltage (AC)Test VoltageFeaturesHeightLengthWidthThicknessMaterial Flammability RatingRadiation HardeningREACH SVHCRoHS StatusFlammability RatingLead Free
Image Part # Manufacturer Description Availability Pricing Quantity Factory Lead TimeContact PlatingMountMounting TypePackage / CaseMaterialHousing MaterialWeightContact MaterialsCurrent-IECCurrent-ULInsulation MaterialsVoltage RatedVoltage-IECOperating TemperaturePackagingPublishedSeriesTolerancePbfree CodePart StatusMoisture Sensitivity Level (MSL)TerminationECCN CodeConnector TypeTypeResistanceNumber of PositionsMin Operating TemperatureColorNumber of RowsGenderAdditional FeatureHTS CodePower RatingVoltage - Rated DCPitchOrientationDepthInsulation HeightReach Compliance CodeCurrent RatingTermination StyleVoltage - Rated ACCase Code (Metric)Approval AgencyCase Code (Imperial)Lead PitchNumber of ContactsContact GenderHousing ColorVoltageContact Tail LengthMax Supply VoltageMax Voltage Rating (AC)Max Current RatingNumber of LevelsCurrentWire Gauge (Max)Wire Gauge (Min)Wire/Cable GaugeNumber of PolesContact Mating FinishNumber of DecksWire Gauge or Range - AWGPositions Per LevelNumber of WaysSafety ApprovalPlug Wire EntryHeader OrientationWire Gauge or Range - mm²Wire Strip LengthNumber of Positions Per LevelScrew SizeStripping LengthWire Cross SectionFastening MethodMax Supply Voltage (DC)Max Supply Voltage (AC)Test VoltageFeaturesHeightLengthWidthThicknessMaterial Flammability RatingRadiation HardeningREACH SVHCRoHS StatusFlammability RatingLead Free
Phoenix Contact 1757035
Mfr. Part #
1757035
Twicea Part #
629-294-1757035
Phoenix Contact
TERM BLOCK PLUG 4POS STR 5.08MM
Datasheet Compare
4442 In Stock
    Min.:1
    Mult.:1
    5 Weeks Tin Cable, Free Hanging Free Hanging (In-Line) - - Polyamide (PA), Nylon 127.999996g - - - Nylon 250V 630V - Bulk 1999 COMBICON MSTB - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Male - - - - 0.200 5.08mm Straight 18.2mm 0.591 15.00mm - 12A Screw - Rising Cage Clamp 250V - CB, CSA, UL, VDE, cULus - 5.08mm 4 - - 300V - 250V - 12A 1 15A 12 AWG 24 AWG 24 AWG - - 1 12-30 AWG - 4 CB; CSA; CUL; EAC; UL; VDE 180° - 0.2-2.5mm2 - - M3 7mm 2.5 mm2 - - - - Retention Latches (Non-Wire Side) 18.3mm 20.32mm 20.32mm - UL94 V-0 No No SVHC RoHS Compliant UL94 V-0 Lead Free
    1757035
    1757035

    629-294-1757035 Phoenix Contact
    RoHS :
    Package : -
    In Stock : 4442
    1 : -
    Phoenix Contact 1757022
    Mfr. Part #
    1757022
    Twicea Part #
    629-294-1757022
    Phoenix Contact
    TERM BLOCK PLUG 3POS STR 5.08MM
    Datasheet Compare
    50000 In Stock
      Min.:1
      Mult.:1
      5 Weeks Tin Cable, Free Hanging Free Hanging (In-Line) - - Polyamide (PA), Nylon 127.999996g - - - Nylon 250V 630V - Bulk 1999 COMBICON MSTB - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Male STANDARD: UL 94V-0, PA, SAFETY APPROVAL :VDE - - - 0.200 5.08mm Right Angle 18.2mm 0.591 15.00mm - 12A Screw - Rising Cage Clamp 250V - UL, VDE - 5.08mm 3 - - 300V - 250V - 12A 1 15A 30 AWG 12 AWG - - - 1 12-30 AWG - 3 CB; CCA; CSA; CUL; EAC; UL 180° - 0.2-2.5mm2 7mm - M3 - 2.5 mm2 - - - - Retention Latches (Non-Wire Side) 15.24mm 15.24mm 18.3mm - UL94 V-0 No - RoHS Compliant UL94 V-0 Lead Free
      1757022
      1757022

      629-294-1757022 Phoenix Contact
      RoHS :
      Package : -
      In Stock : 50000
      1 : -
      Phoenix Contact 1755736
      Mfr. Part #
      1755736
      Twicea Part #
      629-294-1755736
      Phoenix Contact
      TERM BLOCK HDR 2POS VERT 5.08MM
      Datasheet Compare
      4738 In Stock
        Min.:1
        Mult.:1
        7 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 154.999997g - - - - - 630V - Bulk 2010 COMBICON MSTBVA - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - -40°C Green 1 Male STANDARD: UL 94V-0, PA, SAFETY APPROVAL: VDE 8536.69.40.40 - 250V 0.200 5.08mm Straight 8.6mm 0.472 12.00mm - 12A Solder 250V - CB, CSA, UL, VDE, cULus - 5.08mm - - - 300V 0.154 3.90mm - - 12A 1 12A - - - 2 - 1 - - 2 CB; CCA; CSA; CUL; EAC; UL - Vertical - - - - - - CONNECTOR - - - - 12.15mm 12.16mm 15.9mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
        1755736
        1755736

        629-294-1755736 Phoenix Contact
        RoHS :
        Package : -
        In Stock : 4738
        1 : -
        Phoenix Contact 1803280
        Mfr. Part #
        1803280
        Twicea Part #
        629-294-1803280
        Phoenix Contact
        TERM BLOCK HDR 3POS 90DEG 3.81MM
        Datasheet Compare
        24 In Stock
          Min.:1
          Mult.:1
          7 Weeks - Through Hole Through Hole - - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2003 COMBICON MC - yes Active 1 (Unlimited) - EAR99 - Header, Male Pins, Shrouded (4 Side) - - - Green 1 - PBT, UL 94V-0, SAFETY APPROVAL VDE - - 640mV 0.150 3.81mm Right Angle 9.2mm 0.285 7.25mm - 8A Solder 160V - CSA, UL - 3.81mm - Male - 300V 0.134 3.40mm - - 8A 1 8A - - - 3 Tin 1 - - 3 CCA; CB; CSA; CUL; GOST; UL - 90°, Right Angle - - - - - - CONNECTOR - - 2.5kV - - 12.82mm 18.7mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
          1803280
          1803280

          629-294-1803280 Phoenix Contact
          RoHS :
          Package : -
          In Stock : 24
          1 : -
          Phoenix Contact 1757242
          Mfr. Part #
          1757242
          Twicea Part #
          629-294-1757242
          Phoenix Contact
          TERM BLOCK HDR 2POS 90DEG 5.08MM
          Datasheet Compare
          1120 In Stock
            Min.:1
            Mult.:1
            7 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 152.999995g - - - - 250V 400V -40°C Bulk 2001 COMBICON MSTBA - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - 2 - Green 1 Male STANDARD: UL 94V-0, PA, SAFETY APPROVAL :VDE 8536.69.40.40 - 320V 0.200 5.08mm Right Angle 12mm 0.339 8.61mm - 12A Solder - - CSA, EN, UL, VDE - 5.08mm - - - 300V 0.138 3.50mm - - 12A 1 15A - - - 2 - 1 - - 2 CB; CCA; CSA; CUL; EAC; UL - 90°, Right Angle - - - - - - CONNECTOR - - - - 12.08mm 12.16mm 12.1mm 5.08mm UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
            1757242
            1757242

            629-294-1757242 Phoenix Contact
            RoHS :
            Package : -
            In Stock : 1120
            1 : -
            Phoenix Contact 1757077
            Mfr. Part #
            1757077
            Twicea Part #
            629-294-1757077
            Phoenix Contact
            TERM BLOCK PLUG 8POS STR 5.08MM
            Datasheet Compare
            600 In Stock
              Min.:1
              Mult.:1
              5 Weeks Tin Cable, Free Hanging Free Hanging (In-Line) - - Polyamide (PA), Nylon 127.999996g - - - Nylon 250V 630V - Bulk 2001 COMBICON MSTB - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Male PA, 94V-0 - - - 0.200 5.08mm Right Angle 18.2mm 0.591 15.00mm - 12A Screw - Rising Cage Clamp 250V - CB, CSA, UL, VDE, cULus - 5.08mm 8 - - 300V - - 250V 12A 1 15A 12 AWG 24 AWG 24 AWG - - 1 12-30 AWG - 8 UL 180° - 0.2-2.5mm2 - - M3 7mm 2.5 mm2 CONNECTOR 250V 250V - Retention Latches (Non-Wire Side) 18.3mm 40.64mm 40.64mm - UL94 V-0 No No SVHC RoHS Compliant UL94 V-0 Lead Free
              1757077
              1757077

              629-294-1757077 Phoenix Contact
              RoHS :
              Package : -
              In Stock : 600
              1 : -
              Phoenix Contact 1803277
              Mfr. Part #
              1803277
              Twicea Part #
              629-294-1803277
              Phoenix Contact
              TERM BLOCK HDR 2POS 90DEG 3.81MM
              Datasheet Compare
              561 In Stock
                Min.:1
                Mult.:1
                7 Weeks Tin Surface Mount Through Hole 1205 - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2003 COMBICON MC 5% yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) 10kOhm - -40°C Green 1 Male PBT, UL 94V-0 8536.69.40.40 248mW 640mV 0.150 3.81mm Right Angle 9.2mm 0.285 7.25mm - 8A Solder 160V 3216 CSA, UL 1206 3.81mm - - - 300V 0.134 3.40mm - - 8A 1 8A - - - 2 - 1 - - 2 CB; CSA; CUL; GOST; UL; VDE - 90°, Right Angle - - - - - - CONNECTOR - - - - 609.6μm 3.2004mm 1.6002mm - UL94 V-0 No No SVHC RoHS Compliant UL94 V-0 Lead Free
                1803277
                1803277

                629-294-1803277 Phoenix Contact
                RoHS :
                Package : -
                In Stock : 561
                1 : -
                Phoenix Contact 1755794
                Mfr. Part #
                1755794
                Twicea Part #
                629-294-1755794
                Phoenix Contact
                TERM BLOCK HDR 8POS VERT 5.08MM
                Datasheet Compare
                100 In Stock
                  Min.:1
                  Mult.:1
                  12 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 154.999997g - - - - - 630V - Bulk 2001 COMBICON MSTBVA - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - -40°C Green 1 Male STANDARD: UL 94V-0, PA - - 250V 0.200 5.08mm Straight 8.6mm 0.472 12.00mm - 12A Solder 250V - CB, CSA, UL, VDE, cULus - 5.08mm - - - 300V 0.154 3.90mm - - 12A 1 12A - - - 8 - 1 - - 8 CB; CSA; CUL; EAC; UL; VDE - Vertical - - - - - 2.5 mm2 CONNECTOR - - - - 12.15mm 42.64mm 42.64mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                  1755794
                  1755794

                  629-294-1755794 Phoenix Contact
                  RoHS :
                  Package : -
                  In Stock : 100
                  1 : -
                  Phoenix Contact 1803293
                  Mfr. Part #
                  1803293
                  Twicea Part #
                  629-294-1803293
                  Phoenix Contact
                  TERM BLOCK HDR 4POS 90DEG 3.81MM
                  Datasheet Compare
                  648 In Stock
                    Min.:1
                    Mult.:1
                    7 Weeks Tin Through Hole Through Hole - - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2003 COMBICON MC - yes Active 1 (Unlimited) - EAR99 - Header, Male Pins, Shrouded (4 Side) - - - Green 1 - - - - 640mV 0.150 3.81mm Right Angle 9.2mm 0.285 7.25mm - 8A Solder 160V - CSA, UL - 3.81mm - Male - 300V 0.134 3.40mm - - 8A 1 8A - - - 4 - 1 - - 4 CB; CCA; CSA; CUL; EAC; UL - 90°, Right Angle - - - - - - CONNECTOR - - 2.5kV - 7.4mm 16.63mm 18.7mm - UL94 V-0 - - RoHS Compliant UL94 V-0 Lead Free
                    1803293
                    1803293

                    629-294-1803293 Phoenix Contact
                    RoHS :
                    Package : -
                    In Stock : 648
                    1 : -
                    Phoenix Contact 1759033
                    Mfr. Part #
                    1759033
                    Twicea Part #
                    629-294-1759033
                    Phoenix Contact
                    TERM BLOCK HDR 4POS 90DEG 5.08MM
                    Datasheet Compare
                    653 In Stock
                      Min.:1
                      Mult.:1
                      7 Weeks - Through Hole Through Hole - - Polyamide (PA), Nylon 151.999994g Copper, Tin - - - 250V 400V - Bulk 2003 COMBICON MSTB - yes Active 1 (Unlimited) - EAR99 - Header, Male Pins, Shrouded (2 Side) - 4 - Green 1 - - - - 320V 0.200 5.08mm Right Angle 12mm 0.339 8.61mm - 12A Solder - - CSA, EN, UL, VDE - - - - - 300V 0.138 3.50mm - - 12A 1 15A - - - 4 Tin 1 - - 4 UL - 90°, Right Angle - - - - - - - - - - - 12.1mm 20.32mm 20.32mm 15.24mm UL94 V-0 - - RoHS Compliant UL94 V-0 Lead Free
                      1759033
                      1759033

                      629-294-1759033 Phoenix Contact
                      RoHS :
                      Package : -
                      In Stock : 653
                      1 : -
                      Phoenix Contact 1803439
                      Mfr. Part #
                      1803439
                      Twicea Part #
                      629-294-1803439
                      Phoenix Contact
                      TERM BLOCK HDR 3POS VERT 3.81MM
                      Datasheet Compare
                      2000 In Stock
                        Min.:1
                        Mult.:1
                        7 Weeks Tin Through Hole Through Hole - - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2001 COMBICON MCV - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - - Green 1 Male STANDARD: UL 94V-0, PBT, SAFETY APPROVAL: VDE - - 640mV 0.150 3.81mm Straight 7.25mm 0.362 9.20mm - 8A Solder 160V - CB, CSA, UL, VDE, cULus - 3.81mm - - - 300V 0.134 3.40mm - - 8A 1 8A - - - 3 - 1 - - 3 CB; CCA; CSA; CUL; EAC; UL - Vertical - - - - - - CONNECTOR - - - - 12.6mm 12.82mm 12.82mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                        1803439
                        1803439

                        629-294-1803439 Phoenix Contact
                        RoHS :
                        Package : -
                        In Stock : 2000
                        1 : -
                        Phoenix Contact 1755778
                        Mfr. Part #
                        1755778
                        Twicea Part #
                        629-294-1755778
                        Phoenix Contact
                        TERM BLOCK HDR 6POS VERT 5.08MM
                        Datasheet Compare
                        180 In Stock
                          Min.:1
                          Mult.:1
                          7 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 154.999997g Tin 12A 12A - 250V 630V - Bulk 2005 COMBICON MSTBVA - - Active 1 (Unlimited) Solder - Plug Header, Male Pins, Shrouded (4 Side) - 6 - Green 1 Male - - - 250V 0.200 5.08mm Straight 8.6mm 0.472 12.00mm - 12A Solder 250V - CB, CSA, UL, VDE, cULus - 5.08mm 6 - Green 300V 0.154 3.90mm - - 12A 1 12A - - - 6 Tin - - 6 - - - Vertical - - 6 - - - - - - - - 15.9mm 32.48mm 32.48mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                          1755778
                          1755778

                          629-294-1755778 Phoenix Contact
                          RoHS :
                          Package : -
                          In Stock : 180
                          1 : -
                          Phoenix Contact 1827716
                          Mfr. Part #
                          1827716
                          Twicea Part #
                          629-294-1827716
                          Phoenix Contact
                          Conn Terminal Block F 3 POS 3.81mm Screw RA Cable Mount 8A
                          Datasheet Compare
                          12500 In Stock
                            Min.:1
                            Mult.:1
                            5 Weeks - Cable, Free Hanging Free Hanging (In-Line) - Polyamide Polyamide (PA), Nylon 98.999993g Copper - - - 160V 320V - Bulk 2008 COMBICON MC - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Female PA, 94V-0 - - - 0.150 3.81mm Right Angle 11.1mm 0.437 11.10mm not_compliant 8A Screw - Rising Cage Clamp - - CB, CSA, UL, VDE, cULus - - 3 - - 300V - - - 8A 1 8A 16 AWG 28 AWG - - Tin 1 14-30 AWG - 3 UL 180° - 0.14-1.5mm2 7mm - M2 - - - - - - Mating Flange 16.1mm 21.82mm 16.1mm - UL94 V-0 - - RoHS Compliant UL94 V-0 Lead Free
                            1827716
                            1827716

                            629-294-1827716 Phoenix Contact
                            RoHS :
                            Package : -
                            In Stock : 12500
                            1 : -
                            Phoenix Contact 1803426
                            Mfr. Part #
                            1803426
                            Twicea Part #
                            629-294-1803426
                            Phoenix Contact
                            TERM BLOCK HDR 2POS VERT 3.81MM
                            Datasheet Compare
                            500 In Stock
                              Min.:1
                              Mult.:1
                              7 Weeks Tin Through Hole Through Hole - - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2001 COMBICON MCV - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - - Green 1 Male STANDARD: UL 94V-0, PBT, SAFETY APPROVAL: VDE 8536.69.40.40 - 640mV 0.150 3.81mm Straight 7.25mm 0.362 9.20mm - 8A Solder 160V - CB, CSA, UL, VDE, cULus - 3.81mm - - - 160V 0.134 3.40mm - - 8A 1 8A - - - 2 - 1 - - 2 CB; CCA; CSA; CUL; EAC; UL - Vertical - - - - - - CONNECTOR - - - - 9.01mm 9.01mm 12.6mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                              1803426
                              1803426

                              629-294-1803426 Phoenix Contact
                              RoHS :
                              Package : -
                              In Stock : 500
                              1 : -
                              Phoenix Contact 1757051
                              Mfr. Part #
                              1757051
                              Twicea Part #
                              629-294-1757051
                              Phoenix Contact
                              TERM BLOCK PLUG 6POS STR 5.08MM
                              Datasheet Compare
                              23 In Stock
                                Min.:1
                                Mult.:1
                                5 Weeks Tin Cable, Free Hanging Free Hanging (In-Line) - - Polyamide (PA), Nylon 127.999996g - - - Nylon 250V 630V - Bulk 2008 COMBICON MSTB - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Female PA, UL 94V-0 - - - 0.200 5.08mm Right Angle 18.2mm 0.591 15.00mm - 12A Screw - Rising Cage Clamp 250V - UL, VDE - 5.08mm 6 - - 300V - 250V - 12A 1 15A 30 AWG 12 AWG - - - 1 12-30 AWG - 6 CB; CSA; CUL; GOST; UL; VDE 180° - 0.2-2.5mm2 7mm - M3 - 2.5 mm2 - - - - Retention Latches (Non-Wire Side) 18.3mm 30.48mm 30.48mm - UL94 V-0 No - RoHS Compliant UL94 V-0 Lead Free
                                1757051
                                1757051

                                629-294-1757051 Phoenix Contact
                                RoHS :
                                Package : -
                                In Stock : 23
                                1 : -
                                Phoenix Contact 1757019
                                Mfr. Part #
                                1757019
                                Twicea Part #
                                629-294-1757019
                                Phoenix Contact
                                TERM BLOCK PLUG 2POS STR 5.08MM
                                Datasheet Compare
                                50000 In Stock
                                  Min.:1
                                  Mult.:1
                                  5 Weeks Tin Cable, Free Hanging Free Hanging (In-Line) - - Polyamide (PA), Nylon 127.999996g - - - Nylon 250V 630V - Bulk 1999 COMBICON MSTB - yes Active 1 (Unlimited) Screw EAR99 Screw, Socket Plug, Female Sockets - - - Green 1 Receptacle POLYAMIDE, 94V-0 8536.69.40.40 - - 0.200 5.08mm Right Angle 18.2mm 0.591 15.00mm - 12A Screw - Rising Cage Clamp 250V - UL, VDE - 5.08mm 2 - - 300V - 250V - 12A 1 15A 12 AWG 24 AWG 24 AWG - - 1 12-30 AWG - 2 UL; CSA 180° - 0.2-2.5mm2 7mm - M3 - - CONNECTOR - - - Retention Latches (Non-Wire Side) 15mm 10.16mm 18.3mm - UL94 V-0 No No SVHC RoHS Compliant UL94 V-0 Lead Free
                                  1757019
                                  1757019

                                  629-294-1757019 Phoenix Contact
                                  RoHS :
                                  Package : -
                                  In Stock : 50000
                                  1 : -
                                  Phoenix Contact 1803455
                                  Mfr. Part #
                                  1803455
                                  Twicea Part #
                                  629-294-1803455
                                  Phoenix Contact
                                  TERM BLOCK HDR 5POS VERT 3.81MM
                                  Datasheet Compare
                                  518 In Stock
                                    Min.:1
                                    Mult.:1
                                    7 Weeks Tin Through Hole Through Hole - - Polybutylene Terephthalate (PBT) 113.398093g - - - - - 250V - Bulk 2001 COMBICON MCV - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - - Green 1 Male STANDARD: UL 94V-0, PBT, SAFETY APPROVAL: VDE - - 640mV 0.150 3.81mm Straight 7.25mm 0.362 9.20mm - 8A Solder 160V - CSA, UL - 3.81mm - - - 300V 0.134 3.40mm - - 8A 1 8A - - - 5 - 1 - - 5 CB; CCA; CSA; CUL; EAC; UL - Vertical - - - - - - CONNECTOR - - - - 12.6mm 20.44mm 20.44mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                                    1803455
                                    1803455

                                    629-294-1803455 Phoenix Contact
                                    RoHS :
                                    Package : -
                                    In Stock : 518
                                    1 : -
                                    Phoenix Contact 1757307
                                    Mfr. Part #
                                    1757307
                                    Twicea Part #
                                    629-294-1757307
                                    Phoenix Contact
                                    TERM BLOCK HDR 8POS 90DEG 5.08MM
                                    Datasheet Compare
                                    2700 In Stock
                                      Min.:1
                                      Mult.:1
                                      7 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 152.999995g - - - - - 400V - Bulk 2001 COMBICON MSTBA - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - -40°C Green 1 Male STANDARD: UL 94V-0, PBT - - 320V 0.200 5.08mm Right Angle 12mm 0.339 8.61mm - 12A Solder 250V - CSA, EN, UL, VDE - 5.08mm - - - 300V 0.138 3.50mm - - 12A 1 15A - - - 8 - 1 - - 8 CB; CSA; GOST; UL; VDE - 90°, Right Angle - - - - - - CONNECTOR - - - - 8.75mm 42.64mm 42.56mm 35.56mm UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                                      1757307
                                      1757307

                                      629-294-1757307 Phoenix Contact
                                      RoHS :
                                      Package : -
                                      In Stock : 2700
                                      1 : -
                                      Phoenix Contact 1755749
                                      Mfr. Part #
                                      1755749
                                      Twicea Part #
                                      629-294-1755749
                                      Phoenix Contact
                                      TERM BLOCK HDR 3POS VERT 5.08MM
                                      Datasheet Compare
                                      2828 In Stock
                                        Min.:1
                                        Mult.:1
                                        7 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 154.999997g Tin 12A 12A - 250V 630V - Bulk 2005 COMBICON MSTBVA - - Active 1 (Unlimited) Solder - Plug Header, Male Pins, Shrouded (4 Side) - 3 - Green 1 - - - - 250V 0.200 5.08mm Straight 8.6mm 0.472 12.00mm - 12A Solder 250V - CB, CSA, UL, VDE, cULus - 5.08mm 3 - Green 300V 0.154 3.90mm - - 12A 1 12A - - - 3 Tin - - 3 - - - Vertical - - 3 - - - - - - - - 15.9mm 17.24mm 17.24mm - UL94 V-0 - - RoHS Compliant UL94 V-0 Lead Free
                                        1755749
                                        1755749

                                        629-294-1755749 Phoenix Contact
                                        RoHS :
                                        Package : -
                                        In Stock : 2828
                                        1 : -
                                        Phoenix Contact 1755752
                                        Mfr. Part #
                                        1755752
                                        Twicea Part #
                                        629-294-1755752
                                        Phoenix Contact
                                        TERM BLOCK HDR 4POS VERT 5.08MM
                                        Datasheet Compare
                                        405 In Stock
                                          Min.:1
                                          Mult.:1
                                          12 Weeks Tin Through Hole Through Hole - - Polyamide (PA), Nylon 154.999997g - - - - - 630V - Bulk 2001 COMBICON MSTBVA - yes Active 1 (Unlimited) - EAR99 Plug Header, Male Pins, Shrouded (4 Side) - - -40°C Green 1 Male - - - 250V 0.200 5.08mm Straight 8.6mm 0.472 12.00mm - 12A Solder 250V - CB, CSA, UL, VDE, cULus - 5.08mm - - - 300V 0.154 3.90mm - - 12A 1 12A - - - 4 - 1 - - 4 CB; CSA; CUL; EAC; EN; UL; VDE - Vertical - - - - - - CONNECTOR - - - - 12.15mm 22.32mm 22.32mm - UL94 V-0 - No SVHC RoHS Compliant UL94 V-0 Lead Free
                                          1755752
                                          1755752

                                          629-294-1755752 Phoenix Contact
                                          RoHS :
                                          Package : -
                                          In Stock : 405
                                          1 : -
                                          • 1
                                          • ..
                                          • 1
                                          • 2
                                          • 3
                                          • 4
                                          • ..
                                          • 50

                                          Connectors, Interconnects

                                          Terminal Blocks - Headers, Plugs and Sockets definition: A terminal block is an accessory product used to achieve electrical connections, and is industrially divided into the category of connectors... Terminal Blocks - Headers, Plugs and Sockets Product Listing: 1757035,1757022,1755736,1803280,1757242.Connectors, Interconnects type:Circular Connectors(4568089),Barrel - Audio Connectors(714841),Rectangular Connectors - Headers, Male Pins(577481),Card Edge Connectors - Edgeboard Connectors(554593),D-Sub Connectors(513416) .Terminal Blocks - Headers, Plugs and Sockets has 10000 pieces of spot stock price information, you can click the "RFQ" button to confirm the inventory and price with the Twicea.
                                          Index :
                                          0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ

                                          Contact us

                                          Email us
                                          info@twicea.com
                                          Address:
                                          UNIT 3,6/F KAM HON IND BLDG 8 WANG KWUN RD KOWLOON BAY HONG KONG

                                          Quick Links

                                          About us Shipment Terms & Conditions Privacy Policy Cookies Policy

                                          Keep up to date with the TWICEA offer:

                                          Pay online using:

                                          PaypalVISAAmexMaster-cardMaster
                                          Twicea © Copyright 2023, Inc. All rights reserved