| Image | Part # | Manufacturer | Description | Availability | Pricing | Quantity | Factory Lead Time | Mount | Mounting Type | Package / Case | Number of Pins | Weight | Operating Temperature | Published | Series | Part Status | Moisture Sensitivity Level (MSL) | Termination | Type | Max Operating Temperature | Min Operating Temperature | Voltage - Supply | Current Rating | Frequency | Termination Style | Number of Outputs | Output Type | Operating Supply Voltage | Cable Length | Throw Configuration | Response Time | Contact Form | Number of Inputs | Power Consumption | Contact Rating @ Voltage | Sensitivity | Features | Distance - Control To Sensor (Max) | Height | Length | Width | REACH SVHC | RoHS Status | Lead Free |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr. Part #PNRT110ATwicea Part #182-438-PNRT110A | Crouzet |
CNTRL LIQ LEV 110VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 25 Weeks | Plug-In, Socketable | Socketable | - | 8 | 0.441lb 200.03g | -10°C~60°C | 2003 | NRT | Obsolete | 1 (Unlimited) | Plug | Constant Level | - | - | 110VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | - | - | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 0 ~ 100k Ω | - | 91.44m | - | - | - | - | Non-RoHS Compliant | - | ||
| PNRT110A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PNRU220ATwicea Part #182-438-PNRU220A | Crouzet |
CNTRL LIQ LEV 220VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | - | Socketable | - | 8 | 0.441lb 200.03g | -10°C~60°C | 2003 | NRU | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 220VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | 2W | 10A @ 250VAC | 4.7k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | Unknown | Non-RoHS Compliant | - | ||
| PNRU220A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #LNRU110ATwicea Part #182-438-LNRU110A | Crouzet |
CNTRL LIQ LEV 110VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 25 Weeks | DIN Rail, Socketable | Socketable | - | 11 | 0.441lb 200.03g | -10°C~60°C | 2003 | NRU | Active | 1 (Unlimited) | Plug | High/Low Level | 60°C | -10°C | 110VAC | 10A | 833MHz | Plug In, 11 Pin (Octal) | 1 | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | 1 | 2W | 10A @ 250VAC | 4.7kOhm ~ 100kOhm | Adjustable Sensitivity | 91.44m | - | - | - | - | RoHS Compliant | - | ||
| LNRU110A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #DNRU220ATwicea Part #182-438-DNRU220A | Crouzet |
CONTROL LIQ LEV 220VAC DIN RAIL
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | DIN Rail | DIN Rail | - | - | 0.441lb 200.03g | -10°C~60°C | 2003 | NRU | Obsolete | 1 (Unlimited) | Screw | High/Low Level | - | - | 220VAC | - | - | Screw Terminal | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 4.7k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | Non-RoHS Compliant | - | ||
| DNRU220A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PNRU24ATwicea Part #182-438-PNRU24A | Crouzet |
CONTROL LIQ LEV 24VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | Socketable | Socketable | - | 8 | 0.441lb 200.03g | -10°C~60°C | 2003 | NRU | Obsolete | 1 (Unlimited) | Plug | High/Low Level | 60°C | -10°C | 24VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 4.7kOhm ~ 100kOhm | Adjustable Sensitivity | 91.44m | - | - | - | - | Non-RoHS Compliant | - | ||
| PNRU24A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870203Twicea Part #182-438-84870203 | Crouzet |
CONTROL LIQ LEV 120VAC DIN RAIL
Datasheet
Compare
| Min.:1 Mult.:1 | 5 Weeks | DIN Rail | DIN Rail | 120 | - | 0.331lb 150.14g | -20°C~50°C | 2003 | ENR | Active | Not Applicable | Screw | High/Low Level | 50°C | -20°C | 120VAC | - | 833MHz | Screw Terminal | 1 | Relay | 120V | - | SPDT | 300 ms | SPDT (1 Form C) | 1 | 3W | 8A @ 240VAC | 5kOhm ~ 100kOhm | Adjustable Sensitivity | - | 78mm | 22.5mm | 22.5mm | Unknown | RoHS Compliant | - | ||
| 84870203 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PNRT24ATwicea Part #182-438-PNRT24A | Crouzet |
CONTROL LIQ LEV 24VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | - | Socketable | - | 8 | 0.441lb 200.03g | -10°C~60°C | 2003 | NRT | Obsolete | 1 (Unlimited) | Plug | Constant Level | - | - | 24VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 0 ~ 100k Ω | Delay Timer | - | - | - | - | - | RoHS Compliant | - | ||
| PNRT24A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PNR24ATwicea Part #182-438-PNR24A | Crouzet |
CONTROL LIQ LEV 24VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | - | Socketable | - | 8 | 0.287lb 130.18g | -10°C~60°C | 2004 | NR | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 24VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 4.7k Ω ~ 100k Ω | - | - | - | - | - | - | Non-RoHS Compliant | - | ||
| PNR24A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870211Twicea Part #182-438-84870211 | Crouzet |
CONTROL LIQ LEVEL 24VAC DIN RAIL
Datasheet
Compare
| Min.:1 Mult.:1 | 5 Weeks | DIN Rail | DIN Rail | - | - | 0.331lb 150.14g | -20°C~50°C | 2003 | ENRM | Active | 1 (Unlimited) | Screw | High/Low Level | - | - | 24VAC | - | - | Screw Terminal | - | Relay | - | - | SPDT | - | SPDT (1 Form C) | 1 | - | 8A | 250 Ω ~ 1M Ω | Adjustable Sensitivity, Delay Timer | - | - | - | - | - | RoHS Compliant | - | ||
| 84870211 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870504Twicea Part #182-438-84870504 | Crouzet |
CONTROL LIQ LEV 230VAC DIN RAIL
Datasheet
Compare
| Min.:1 Mult.:1 | 5 Weeks | Chassis Mount, DIN Rail | Chassis Mount, DIN Rail | - | - | 0.617lb 279.87g | -20°C~60°C | 2005 | FN | Obsolete | 1 (Unlimited) | Screw | High/Low Level | - | - | 230VAC | - | - | Screw Terminal | - | Relay (2) | 230V | - | SPDT | - | SPDT (2 Form C) | - | - | 8A @ 250VAC | 5k Ω ~ 100k Ω | Alarm High/Low - Contact | - | 99.3mm | 103.5mm | 45mm | - | RoHS Compliant | - | ||
| 84870504 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #NNR110ATwicea Part #182-438-NNR110A | Crouzet |
CONTROL LIQ LEVEL 110VAC CHASSIS
Datasheet
Compare
| Min.:1 Mult.:1 | 17 Weeks | Chassis Mount, PCB | Chassis Mount | - | - | 0.286lb 129.73g | -10°C~60°C | 2004 | NNR | Obsolete | 1 (Unlimited) | Quick Connect | High/Low Level | 60°C | -10°C | 110VAC | 10A | 833MHz | Quick Connect - 0.250 (6.3mm) | 1 | Relay | - | - | - | - | SPDT (1 Form C) | 1 | 2W | 10A @ 250VAC | 4.7kOhm ~ 47kOhm | Adjustable Sensitivity | - | 54.9mm | 91.9mm | - | Unknown | Non-RoHS Compliant | Lead Free | ||
| NNR110A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #NNR220ATwicea Part #182-438-NNR220A | Crouzet |
CONTROL LIQ LEVEL 220VAC CHASSIS
Datasheet
Compare
| Min.:1 Mult.:1 | 10 Weeks | Chassis Mount, Screw | Chassis Mount | - | - | 0.286lb 129.73g | -10°C~60°C | 2004 | NNR | Obsolete | 1 (Unlimited) | Quick Connect | High/Low Level | 60°C | -10°C | 220VAC | - | - | Quick Connect - 0.250 (6.3mm) | - | Relay | - | - | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 4.7kOhm ~ 47kOhm | Adjustable Sensitivity | - | - | - | - | - | Non-RoHS Compliant | - | ||
| NNR220A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870404Twicea Part #182-438-84870404 | Crouzet |
CNTRL LIQ LEV 230VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 8 Weeks | Plug-In, Socketable | Socketable | - | - | 0.309lb 140.16g | -20°C~60°C | 2011 | L2N | Obsolete | 1 (Unlimited) | Plug | High/Low Level (2) | - | - | 230VAC | - | - | Plug In, 11 Pin (Octal) | - | Relay | - | 100m | SPDT | - | SPDT (1 Form C) | 1 | - | 8A | 5k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | RoHS Compliant | - | ||
| 84870404 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870303Twicea Part #182-438-84870303 | Crouzet |
CNTRL LIQ LEV 120VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 8 Weeks | Plug-In, Socketable | Socketable | - | - | 0.309lb 140.16g | -20°C~60°C | 2011 | LN | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 120VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | 100m | SPDT | - | SPDT (1 Form C) | 1 | - | 8A | 5k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | RoHS Compliant | - | ||
| 84870303 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870103Twicea Part #182-438-84870103 | Crouzet |
Liquid Level Control, End Pump Down Only
Datasheet
Compare
| Min.:1 Mult.:1 | - | DIN Rail | DIN Rail | - | - | 0.309lb 140.16g | -20°C~60°C | 2003 | EN | Obsolete | 1 (Unlimited) | Screw | Constant Level | - | - | 120VAC | - | - | Screw Terminal | - | Relay | - | - | - | - | SPDT (1 Form C) | - | - | 8A | 5k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | RoHS Compliant | - | ||
| 84870103 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870401Twicea Part #182-438-84870401 | Crouzet |
CONTROL LIQ LEV 24VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 8 Weeks | Plug-In, Socketable | Socketable | - | 11 | 0.309lb 140.16g | -20°C~60°C | 2011 | L2N | Obsolete | 1 (Unlimited) | Plug | High/Low Level (2) | - | - | 24VAC | - | - | Plug In, 11 Pin (Octal) | - | Relay | - | 100m | SPDT | - | SPDT (1 Form C) | 1 | - | 8A | 5k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | RoHS Compliant | - | ||
| 84870401 | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #LNR24ATwicea Part #182-438-LNR24A | Crouzet |
CONTROL LIQ LEV 24VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | Plug-In, Socketable | Socketable | - | 11 | 0.286lb 129.73g | -10°C~60°C | 2005 | NR | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 24VAC | 10A | 833MHz | Plug In, 11 Pin (Octal) | - | Relay | - | - | SPDT | - | SPDT (1 Form C) | 1 | - | 10A @ 250VAC | 4.7k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | 48mm | - | - | RoHS Compliant | - | ||
| LNR24A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #PNR220ATwicea Part #182-438-PNR220A | Crouzet |
CNTRL LIQ LEV 220VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 15 Weeks | DIN Rail, Socketable | Socketable | - | 8 | 0.286lb 129.73g | -10°C~60°C | 2004 | NR | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 220VAC | - | - | Plug In, 8 Pin (Octal) | - | Relay | - | - | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 4.7k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | Non-RoHS Compliant | - | ||
| PNR220A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #DNRT24ATwicea Part #182-438-DNRT24A | Crouzet |
CONTROL LIQ LEVEL 24VAC DIN RAIL
Datasheet
Compare
| Min.:1 Mult.:1 | 11 Weeks | DIN Rail | DIN Rail | - | - | 0.441lb 200.03g | -10°C~60°C | 2003 | NRT | Obsolete | 1 (Unlimited) | Screw | Constant Level | - | - | 24VAC | - | - | Screw Terminal | - | Relay | - | 91.44m | SPDT | - | SPDT (1 Form C) | - | - | 10A @ 250VAC | 0 ~ 100k Ω | Delay Timer | - | - | - | - | - | Non-RoHS Compliant | - | ||
| DNRT24A | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr. Part #84870309Twicea Part #182-438-84870309 | Crouzet |
CNTRL LIQ LEV 230VAC SOCKETABLE
Datasheet
Compare
| Min.:1 Mult.:1 | 5 Weeks | Plug-In, Socketable | Socketable | - | 11 | 0.309lb 140.16g | -20°C~60°C | 2011 | LN | Obsolete | 1 (Unlimited) | Plug | High/Low Level | - | - | 230VAC | - | - | Plug In, 11 Pin (Octal) | - | Relay | - | 100m | SPDT | - | SPDT (1 Form C) | 1 | - | 8A | 5k Ω ~ 100k Ω | Adjustable Sensitivity | - | - | - | - | - | RoHS Compliant | - | ||
| 84870309 |
Index :
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ